Micromanometer Calibration

January 25, 2010 8:44 pm | Posted by admin

New and cost effective calibrations can be undertaken on all low pressure sensors, micromanometers, multislope manometers down to 5 Pascal full scale. New calibration and control systems are capable of delivering gauge and differential pressure calibrations from 5 – 5000 Pa, with a 0.25 Pa uncertainty. For more information on Pressure Calibration Services please follow the link, along with our UKAS capabilities.

Thermal Imaging Camera Calibration

January 21, 2010 3:40 pm | Posted by admin

Facilities are now available to calibrate all types of thermal imaging cameras and infrared devices. Calibration across a temperature range of 35 to 500 °C can be accomodated using high precision radiometric calibrators. For more information on Temperature Calibration please follow the link.

Expanded Medical Calibration Services

January 3, 2010 12:31 pm | Posted by admin

The company extends its’ medical services support to cover defibrillators, pulse oximetry, tympanic and arterial temperature instruments. All using the latest reference calibration equipment. Defibrillators and AEDs  from all leading manufacturers can be calibrated. Calibration of personal and laboratory pulse oximeters and all vital signs meters can also be undertaken. For more information on Medical Equipment Calibration Services please follow the link.

Ventilator Calibrator Issues

October 27, 2009 8:16 am | Posted by admin

Discussion forum for users and service personnel on issues and problems associated with medical ventilators, during use, service and calibration.

For more information visit UKAS Calibration Services.

Posted in Medical Equipment  | The post has tags: , ,  |  14 Comments »

Anemometer Calibration

October 6, 2009 6:22 pm | Posted by admin

Any topics covered about anemometer calibration, air velocity wind tunnels, blockage effects, calibration techniques and ISO 17025 accreditation.

For more information on Air Velocity Calibration please follow the link.

TML Wireless Temperature Calibration

August 22, 2009 8:08 pm | Posted by admin

The Calibration Services Laboratory can now undertake temperature calibration and pressure calibrations using the wireless TML protocol, saving users, on average of over 14 days in calibration turnaround with the minimum of disruption. Sensors only need be supplied with their respective transmitter module and details, with the rest being supplied by our laboratory. Used extensively in the composting and seed cultivation sectors, the dedicated laboratory systems have become a firm favourite with the UK composters.

Rotating Cup Anemometer Calibration Correlation

August 11, 2009 5:27 pm | Posted by admin

Anyone wishing to be involved in a interlaboratory calibration of a rotating cup anemometer, should contact Chris Lang (cl@youngcalibration.co.uk) A small rotating cup anemometer will be used for the correlation study. Ideally the laboratory should be ISO 17025 accredited.

For more information on calibration testing contact Young Calibration Services.

Oil Flow Calibration Facility

August 1, 2009 10:02 am | Posted by admin

Extension of our UKAS ISO 17025 accreditation schedule was recently achieved for the oil flow meter calibration facility. The calibration facility can now undertake accredited flow calibrations from 0.6 litre/min upto 280 litre/min on oil.

Other inhouse facilities are available to cover fluids such as Shellsol, ISO 4113, Skydrol, AVGas, Jet A1, IPA, engine oils and hydraulic oils. Between the seven test rigs, flow ranges from 1 cc/min up to 1100 litres/min can be  covered.

Posted in Young Calibration News  | The post has tags: , ,  |  7 Comments »

Increased Pressure Calibration Capability

July 27, 2009 8:33 pm | Posted by admin

Traceable pneumatic pressure calibrations can now be completed upto 200 bar. UKAS Pressure calibrations can be completed up to 20 bar pneumatic and 1100 bar hydraulic.  Calibrations are undertaken on a range of Mensor, Druck, Ruska and Degranges & Huot systems.

For more information on pressure calibration services contact Young Calibration Services.

Posted in Young Calibration News  | The post has tags: ,  |  5 Comments »

Gemini oval gear meter calibration

July 21, 2009 9:39 pm | Posted by admin
Gemini Gear MeterA recent contract award for the calibration of over 100 Gemini and Macnaght oval gear meters was secured by Young Calibration Services. The various size Gemini / Macnaught flowmeters, covering G05, M05, G1, M1, G2 and M2 models are to have multi point calibrations on the customer fluid, being a flavoured essence.
Calibrations are completed in a temperature and pressure controlled test line with repeatability, and stop / start hysterisis tests undertaken for each individual flowmeter. Units are then chemically sealed and bagged prior to dispatch and return to the customer. The company now provide UKAS accredited oil flow meter calibration from 0.6 to 280 litres/min.
Posted in Young Calibration News  | The post has tags: , ,  |  8 Comments »